Rugged Portable Datalogger with RS-232 output

 OM-190 -  Rugged Portable Datalogger with RS-232 output

The OM-190 is a general purpose datalogger designed to serve a wide variety of applications such as plant maintenance, environmental and process monitoring. It can be used for troubleshooting motors and valves, monitoring process variables such as temperature, pressure, flow and relative humidity as well as other applications. The OM- 190 accepts up to 4 universal input plug in boards that are available in either 4 channel isolated or 4 channel non-isolated models for a total of up to 16 input channels. A particular input channel's measurement configuration is selected via menu selections. Simply connect the nputs to the barrier strips provided on the input boards after channel configuration has been selected. An auxiliary port is provided on the datalogger to accept data packs for off loading data. An RS-232 port is also provided for serial communications between the OM- 190 and a PC. The serial port is capable of 300 to 19.2 Kbaud (38 Kbaud playback only).

Storage Modes
The Model OM-190 datalogger offers five modes of storing data; Adaptive Store, Point Store, Enhanced Point Store, Store on Alarm and Manual Store.

Adaptive Store
Adaptive Store is a process designed to collect data in a most efficient, accurate way allocating memory to data storage based on signal dynamics. The result is that both trends and anomalies are accurately recorded. The datalogger samples as fast as possible to provide a true picture of transients, applying more memory to them than to trend data. The sample rate is fixed at 500 ms for recording lengths under 8 days, 1 second for recording lengths of 8 to 15 days and 2 seconds for recording lengths over 15 days. This is the best mode for capturing anomalies and trend data over long periods of time and is the most efficient use of memory. Maximum recording length is 999 days. Sample rate is always 500 ms with recharger plugged in.

Point Store
The Point Store mode is found in most conventional dataloggers. The storage principal is that every sample taken is stored in memory with its associated time. With the OM-190, you have the ability to select the sample rate and the length of the recording facilitating optimum use of the datalogger's memory. Either variable can be respecified during setup. If the combination of these two variables is not compatible, the last variable programmed is the primary condition and the OM-190 will respecify and display the other to be within the system capability. Available sample intervals are 12, 8, 4, 3, 2 and 1 hours; 30, 15, 10, 5, 2, and 1 minutes; 30, 10, 5, 2 and 1 seconds; 500, 250, 125 and 62.5 ms. The recording length is programmable between 1 second and 999 days, an ideal mode for long term trend recording at fixed intervals.

Enhanced Point Store
This is a variation of Point Store and Adaptive Store modes. In this mode, data is stored as described above in the Point Store mode with the additional advantage of being able to store the maximum and minimum values and their associated times as they occur between the sample interval selected and the average of all samples in the sampling period. This way much more information is available for analysis. The available sample intervals are the same as in Point Store mode, however, the maximum primary rate is 10 seconds. The secondary sample rate is one second for recording of 7 days or less and two seconds for recording longer than 7 days. This mode is the ideal choice for collecting data at required intervals and for detecting anomalies needed for analysis and troubleshooting at the same time. Anomalies are detected and stored because of the faster secondary sample rate.

Store On Alarm
The Store on Alarm mode also offers two alarm storage techniques called Burst and Continuous. In Burst mode, data will be stored for an alarm condition at the secondary sample rate for a predetermined number of samples before and after the alarm detection. Storage will then resume at the primary sample rate. The predetermined number of samples is calculated by the ratio of primary to secondary storage rate with a maximum number of ▒50 for 7 or less channels and a maximum of ▒32 for 16 channels. For xample, if the primary storage rate is every 10 seconds and the secondary storage rate is every one second, then the ratio would be 10 and the number of burst samples would be ▒10 from the alarm threshold. If the primary rate is 30 seconds and the secondary rate is one second, then the number of burst samples would be ▒30.

Manual Store
The Manual Store mode is very useful for collection of data that may not be time related. In this mode, data points are stored for all active hannels at the operators discretion. Storage is initiated by pressing the right hand key on the datalogger for every desired sample to be stored. Each sample is stored with its associated time and date as well as a sample number sequentially assigned by the OM-190. For an OM-190 datalogger with 512K memory, the total number of samples that can be stored for the worst case (32 active channels) would not be less than 7323. For one active channel it would be approximately 83,000.

SWD-PRONTO-WIN Windows Software
Pronto for Windows is a full featured Windows based program that is included with the OM-190 Series dataloggers. Through the use of straightforward macros and keyboard commands, the operator can graph and analyze data and create hard copy reports. Selection of icons from the toolbar makes all commonly used instructions such as zooming, statistical analysis, printing, annotation and playback as easy as pointing and clicking the mouse. File management is greatly improved through the use of projects which define how the data will be stored and grouped and views which define how the data will appear on screen and in reports. Easy to follow dialog boxes provide step-by-step choices for all data management tasks. A multifunctional communication set allows interface to dataloggers by serial port, local area network or modem, all in the same program. A comprehensive context sensitive help system provides detailed instructions anywhere in the program. Interface to other application software such as spreadsheets or word processors is quick and easy using the Windows clipboard or object linking (OLE).